11B-604.8.1.3 Approach
-
11B-604.8.1.3 Approach
Compartments shall be arranged for left-hand or right-hand approach to the water closet....
-
R404.7.2 Parallel Approach
R404.7.2 Parallel Approach. The clear space and additional maneuvering space shall be 1525 mm (5.0 ft) wide minimum where the depth exceeds 380 mm (1.25 ft)....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
Knee and Toe Space [§305.4 and §306]
Knee and toe space allows a closer approach to elements and reduces the reach to operable parts....
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an...
- Access Board: Clear Floor or Ground Space
-
R404.6 Approach
R404.6 Approach. One full unobstructed side of a clear space shall adjoin a pedestrian access route or adjoin another clear space....
-
305.6 Approach
305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an unobstructed forward reach is provided, the operable part must be located 48 inches...
-
Seating [4.32.2] and Knee Clearance [4.32.3]
The over-the-surface reach is limited to 25 inches if at least this much space is available below for knees and toes; (the forward seated reach may not extend beyond the toes)....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
4.34.3(2) Parallel Approach Only
(2) Parallel Approach Only. If only a parallel approach is possible, operable parts of controls shall be placed as follows:...
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
- American Standard Acrylic Shroud for American Standard Selectronic Faucets
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
- Figure 704.2.1.1 Parallel Approach to Telephone – Drawing from the U.S. Access Board
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
- Figure 308.2.1 Unobstructed Forward Reach – Drawing from the U.S. Access Board
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
- Figure 308.2.2 Obstructed High Forward Reach – Drawing from the U.S. Access Board