(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
Search Results "Emergency Transportable Housing Unit"
Commonly Searched Documents
-
3(2)
-
§ 37.42(d)
(d) Before constructing or altering a platform at a station covered by paragraph (c) of this section, at which a railroad proposes to use a means other than level-entry boarding, the...
-
10.4 Airports
[See subsections ...]
-
§ 37.42(d)
(d) Before constructing or altering a platform at a station covered by paragraph (c) of this section, at which a railroad proposes to use a means other than level-entry boarding, the...
-
14 CFR Part 382 Nondiscrimination on the Basis of Disability in Air Travel (Air Carrier Access Act): Preamble and Section-by-Section Analysis (with amendments issued through July 2010)
DEPARTMENT OF TRANSPORTATION 14 CFR Part 382 [Dockets OST–2004–19482; OST–2005–22298; OST–2006–23999] [RINs 2105–AC97; 2105–AC29; 2105–AD41] Nondiscrimination on the Basis of...
-
11B-703.5.6 Height from finish floor or ground
Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.6....
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
A. Purpose and Legal Authority
is responsible for developing accessibility guidelines and standards under various laws to ensure that individuals with disabilities have access to and use of buildings and facilities, transportation...
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the...
-
Trailheads
To comply with the ABA and Section 504 of the Rehabilitation Act of 1973, ensure that each constructed feature provided at a trailhead complies with the applicable provisions of...
-
7.3 Definitions
All trail-related definitions used in the FSTAG are from the Forest Service Manual or Handbook, the Forest Service Infra Trails Module, Trail Assessment and Condition Survey (TRACS)...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.