When public funds are provided by other sources and transferred to a state, county, municipality or other political subdivision of the state, the entity that collects and controls the distribution...
Search Results "Transfer Side"
-
1.9.1.1 Application
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
502.4 Floor or Ground Surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
1009.2 Pool Lifts
Pool lift seats that consist of materials that resist corrosion and provide a firm base to transfer will be usable by a wider range of people with disabilities....
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
4.7.11 Islands
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long between the curb ramps in the part...
-
§ 38.113(a)(1)
(1) At least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this part...
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
The size of this space is determined by the minimum width required for the water closet and lavatory between the side walls, the minimum wheelchair turning space, and the space required...
-
A4.6.3 Parking Spaces
The increasing use of vans with side-mounted lifts or ramps by persons with disabilities has necessitated some revisions in specifications for parking spaces and adjacent access aisles....
- Garaventa Evacu-Trac's Brake Can Stop it on the Stairway
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
R207.1 General
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
Are doors or gates to employee work areas required to comply?
Full compliance of doors or gates on the interior side is recommended, but not required....
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
-
11B-224.2 Guest rooms with mobility features
Provide either a bathtub complying with Section 11B-607 or a transfer type shower complying with Section 11B-608.2.1. 2. ...
-
4.2 Stretchers
They are best known as transport devices for patients in supine, prone, or side-lying positions....
-
1132A.2 Interior doors and secondary exterior doors
The provisions of this section shall apply to the dwelling unit side of doors leading from the interior of the dwelling unit to an unfinished basement or an attached garage....
-
802.1.3 Depth
Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....