Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
Search Results "Transfer Side"
-
802.1.3 Depth
- Bobrick Partition-Mounted Multi-Roll Toilet Tissue Dispenser (Serves 2 Compartments) B-386
- Landscape Forms Inc. Chase Park Trash Receptacle
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
2. Analysis of footrest clearance height and depth
Footrests were present and recorded on the right-side for 101 (64%) manual wheelchair users and 105 (97%) of power wheelchair users....
-
Section 37.9 Standards for Transportation Facilities
One further clarification concerning the implication of this provision deals with a bus loading island at which buses pull up on both sides of the island....
- SDC Z7500 HiTower Pro Series Actuator Controlled Locksets
-
1 [§ 4.7.3]
If the curb ramp has flared sides, which can also be seen in the illustration to the right [below], do not include them in the measurement....
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
5. When Is It Important for My Client to Request a Reasonable Accommodation?
Because an employer does not have to excuse failure to meet production standards that are consistently applied, even if the difficulty was caused by a health condition or the side effects...
-
H15
Is at least one wide toilet stall provided with an out swinging door, side and rear grab bars, and clear space next to the toilet?...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Clear Floor Space [4.27.2]
Clear Floor Space [4.27.2] Clear floor space for a forward or side approach is required at controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed...
-
404.2.7 Door and Gate Hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides....
-
404.2.7 Door and Gate Hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides....
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other....
-
Maneuvering Clearances [§404.2.4]
Clearance beyond the latch side is not required at entry doors to hospital patient rooms. ...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
1132A.1 Primary entry doors and required exit doors
The requirements of Sections 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces (e.g., entry or exit doors which open from the covered...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...