Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
Search Results "Maximum Dimension"
-
11B-703.2.5 Character height
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
§ 38.93(a)(2)
is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where wheelchair or mobility aid users can be accommodated, then such doorway shall have, to the maximum...
-
11B-812.5.4 Arrangement
Vehicle spaces installed in existing facilities shall comply with Section 11B-812.5.4 to the maximum extent feasible....
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum....
-
11B-505.5 Clearance
Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and 18 inches (457 mm) minimum clear above the top of the handrail....
-
608.3.2 Standard Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter "I"....
- Panda TS.83 Thermally Broken Multi-Slide Door System
- Celia 1 Indoor/Outdoor Sconce by Hampstead
- Celia 2 Indoor/Outdoor Sconce by Hampstead
-
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis)
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis) The 2 percent maximum cross slope requirement...
-
Addendum F: Relative Height Differences
Adjustable Height No Grab Bars/No Backrest Maximum Height (n=71) .300 3.5 5.00 9.00 13.7...
-
11B-809.8 Doors
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (102 mm)....
-
Adjustable Height Range Considered
The technical criteria allow the height of transfer surfaces to be either fixed or adjustable within the 17 inches minimum and 19 inches maximum range....
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1134A.8, Item 1
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor....
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”. ...
-
1009.2.1 Pool Lift Location
Where multiple pool lift locations are provided, no more than one pool lift shall be required to be located in an area where the water level is 48 inches (1220 mm) maximum....
-
1009.5.4 Transfer Steps
Transfer step height shall be 8 inches (205 mm) maximum....
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum...
-
407.8.2.2 Obstructed Side Reach
part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches (1170 mm) high maximum...
-
§8.6(c)
result in such an alteration or burdens, the recipient shall take any other action that would not result in such an alteration or such burdens but would nevertheless ensure that, to the maximum...