Continuous handrails are required along both sides of stairs. A center rail is not specified for wide stairways by ADAAG but may be required by local building or life safety codes....
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
Handrails [4.9.4]
-
§ 38.23(c)(4) Ramp barriers
Each side of the ramp shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
- Panda UTS.60 Thermally Broken ULTRA Folding Door System
-
Standing Supports (M304.3 and M305.3)
M304.3 would require standing supports to be provided on each side of the standing surface on diagnostic equipment used by patients in a standing position....
-
1133B.2.3.2
greater than 10 and it is determined that compliance with Section 1133B.2.3 would create an unreasonable hardship, a projection of 5/8 inch (16 mm) maximum will be permitted for the latch side...
-
603 Toilet and Bathing Rooms
Doors are not permitted to swing into clear floor space or clearance required for any fixture except under certain conditions (603.2.3)....
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
Figure 44 Mounting Heights and Clearances for Telephones...
-
4.3.3 Clear Floor Area
The clear floor area width also informs the minimum clearance width for successful passage through corridors, doorways and ramps....
- Zurn Z5958 Series Commercial White, Closed Front Toilet Seat with Cover
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off....
-
R304.5.1 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
407.8.1 Vertical Reference Plane
Operable parts shall be positioned for a side reach or a forward reach determined with respect to a vertical reference plane....
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
-
407.12.1 Vertical Reference Plane
Operable parts shall be positioned for a side reach or a forward reach determined with respect to a vertical reference plane....
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
-
4.34.5.2(1)
The water closet may be located with the clear area at either the right or left side of the toilet....
-
Common Problems with Signs
Problems with Signs Ø    Some signs – such as permanent room signs – are required to have Braille, high contrast, and raised lettering and must be located on the wall to the latch side...
-
Motorized Kick Scooters
Because the user does not normally need to push, these scooters often have a platform wide enough for two adult feet side by side....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
- American Standard AquaWash Telescoping Bidet Seat 5900A.05G
- AJW Architectural Products U685 Series Dual Toilet Tissue Dispenser & Sanitary Napkin Disposal - Partition Mounted
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
T215.2.4 Destination and Route Signs
Where destination or route signs are provided on the exterior of non-rail vehicles, such signs shall be located at a minimum on the front and boarding sides of the vehicle....