The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
Search Results "Clear Opening"
-
11B-411.4.7.3 Symbols
-
11B-606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
§ 38.157(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.2.2
Section 608.2.2 covers the current ADA Standards for the size of standard roll-in type shower compartments.
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
Clearances: ADA Standard Section 1003.3
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.2.3
Section 608.2.3 covers the current ADA Standards for the size and clearances of alternate roll-in type shower compartments.
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
Exercise Equipment and Machines
If the clear space is enclosed on three sides (e.g., by walls or the equipment itself), the clear space must be at least 36 by 48 inches....
-
Temporary Measures
For example, if the only entrance door at a polling place is 29 inches wide, then propping the door open or providing a doorbell for a poll worker to open the door will still not allow a...
-
Compartment Doors
Commenters also pointed out that the specified location should refer to the door opening, instead of the hinge. Response....
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
In addition, areas of refuge are not required in open parking garages, apartment buildings, detention and correctional facilities, or open exit stairways between floors in buildings with...
-
1014.2.1 Transfer Access
the camp shelter, and one full unobstructed side of the clear ground space to adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
Value Contrast (slide 9)
Furniture and open spaces There are so many cases of dark furniture on dark carpeting or on patterned floors, and also white leather furniture on white or very light floors....
- Activar Hiawatha 535/509/536/537 Solid 1 inch Diameter Pulls