We've expanded the Angel City Games from two to four days, adding new sport clinics and competitions including Archery, Swimming, Wheelchair Tennis, Track & Field, and Wheelchair Basketball...
Search Results "Wheelchair Passing Space"
Commonly Searched Documents
- Angel City Sports
-
4.1.2(2)
(2) At least one accessible route complying with 4.3 shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
§ 37.9(b)
This paragraph applies only to alterations of individual elements and spaces and only to the extent that provisions covering those elements or spaces are contained in UFAS or ANSI A117.1...
- Access Board: Toilet Rooms
-
R404.2 Surfaces
Surfaces of clear spaces shall comply with R302.7 and shall have a running slope consistent with the grade of the adjacent pedestrian access route and cross slope of 2 percent maximum....
-
1016.8 Resting Intervals
This section contains the technical requirements for the length (1016.8.1), width (1016.8.2), and slope (1016.8.3) of resting intervals; and for a turning space (1016.8.4) where resting...
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
11B-405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
-
Road Closure Drawings
When foot travel is encouraged on the other side of the barrier, passage for someone in a wheelchair must be provided....
-
CAL Green requires x number of EVSE per xxx number of spaces - each on its own 40 amp circuit. Some dual EVSE are on a single 40 amp circuit and split the 40 amp. Does this mean that half of those plugs don't comply with the required number?
RESPONSE: The California Green Code appears to require service panels, sub-panels, and raceway of sufficient capacity to accommodate 40 amp circuits rather than mandating one 40 amp...
-
1011.2.3 Slope
This section requires the slope of the clear ground space to not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...
- Figure 1003.3.2 (Exception 2) Edge Protection at Boarding Piers – Drawing from the U.S. Access Board
- Figure 1003.3.1 Boat Slip Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.2 Boarding Pier Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips – Drawing from the U.S. Access Board
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
Areas of refuge are fire-resistance rated and smoke protected areas where those unable to use stairs can register a call for evacuation assistance and await instructions or...
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space...