configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is installed on the opening side...
Search Results "Side Transfer"
-
1134A.6, Item 1.3
-
§ 37.131(a)(1)(iv)
(iv) For purposes of this paragraph, the core service area is that area in which corridors with a width of three-fourths of a mile on each side of each fixed route merge together such that...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
-
Handrails
Handrails are required along both sides of ramps and stairs....
-
Mounting Height and Location
Tactile signs are required to be located alongside the latch side of doors so that clear floor space at least 18 by 18 inches, centered on the tactile characters, is provided outside the...
-
407.4.1 Car Dimensions
Table 407.4.1 Elevator Car Dimensions Minimum Dimensions Door Location Door Clear Width Inside Car, Side...
-
4.3.7 Clear Floor Space for Reaching
These dimensions are: (A) occupied width, the horizontal distance between the side-most (lateral-most) points of the wheelchair or occupant on the right and left side; (B) occupied length...
-
§ 36.302(f)(5) Sale of season tickets or other tickets for multiple events
Spectators purchasing tickets for accessible seating on a multi-event basis shall also be permitted to transfer tickets for single-event use by friends or associates in the same fashion...
-
§ 35.138(e) Sale of season tickets or other tickets for multiple events
Spectators purchasing tickets for accessible seating on a multi-event basis shall also be permitted to transfer tickets for single-event use by friends or associates in the same fashion...
-
Engineered vs. Outside
The seat values are of particular importance because vertical vibrations transferred through the seat of a seated individual are the most hazardous....
-
§ 37.201(a)
., operate the lift and provide assistance with securement; provide other boarding assistance if needed, as in the case of a wheelchair user who has transferred to a vehicle seat because...
-
11B-1009.2 Pool lifts
Pool lift seats that consist of materials that resist corrosion and provide a firm base to transfer will be usable by a wider range of people with disabilities....
-
11B-806.2.3.1 Personal lift device floor space
The clearance shall be parallel to the long side of the bed and extend under the bed to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (...
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
Height: ADA Standard Section 704.4.1
accessible telephone because the required 34 inches (865 mm) minimum keypad height can causes the highest operable part of the telephone, usually the coin slot, to exceed the maximum permitted side...
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. ...
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces
Standing supports should be located on one side of the platform, integrated into the platform and stretching the full length of the platform (40 inch minimum) for dual ramped entry raised...
-
M20
Is there a horizontal grab bar at least 36 inches long securely mounted behind the toilet 33 to 36 inches above the floor with one end no more than 6 inches from the side wall?...
-
B1. Slope
Is a relatively level (1:50 or 2% maximum slope in all directions) access aisle provided adjacent and parallel to the side of the vehicle pull-up area?...
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. ...
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
- Hager Companies Door Protection Plate 224S
- Hager Companies Door Protection Plate 223S
-
1015.3 Height
Exceptions: For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, guards on the open sides of stairs shall have a height not less than 34...