The most common configuration is the side-by-side booth, which is pictured below. This model combines one regular height single stations and one ADA Compliant Booth....
Search Results "Side Transfer"
Commonly Searched Documents
- Boolee Multi-Station Voting Booth
-
Dispersion Requirements
Like the proposed rule, specifications are provided for horizontal (side to side) and vertical (front to back) dispersion....
-
4.4.2 Mammography Equipment and Scooters
However, the steering column and other front components of many scooters prevent this necessary proximity without the woman swiveling their seat to a side position....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
4.8.5* HANDRAILS
If a ramp run has a rise greater than 6 in (250 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
-
E. Restaurants and Concessions:
PSE shall ensure that all moveable service counters provide service at the side of the stand....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
Smooth Surface
Section 404.2.10 requires that swinging doors and gates have a smooth surface on the push side that extends their full width....
-
11B-406.5.3 Landings
The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing....
-
11B-504.8 Floor identification
11B-703.2 _|Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-504.8 Floor identification
11B-703.2 _|Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
1023.9 Stairway identification signs
braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
Guidelines for Requirement 5
The inclusion of this additional specification for side approach is consistent with the comparable provisions in the ANSI Standard....
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
Exceptions: In alterations, a projection of 5/8 inch (15.9 mm) maximum into the required clear width shall be permitted for the latch side stop....
-
11B-610.3.1 Rectangular seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall. FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
610.3.1 Rectangular Seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall. Figure 610.3.1 Rectangular Shower Seat...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
802.1.3 Depth
Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...