Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides...
Search Results "Side Entry"
-
402.2 Components
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the sides...
-
4.13.9* Door Hardware
When sliding doors are fully open, operating hardware shall be exposed and usable from both sides....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the sides...
-
Curb Ramps at Intersections
Curb ramps at marked crossings must be wholly contained within the crosswalk, excluding side flares....
-
§ 38.39(b)
width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum character height (using an upper case “X”) of 1 inch for signs on the boarding side...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared sides...
-
11B-810.6.3 Station names
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-802.1.2 Width
It should be noted that although side access to the wheelchair space is allowed, companion seating in compliance with Section 11B-802.3 must also be provided adjacent to each wheelchair...
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
Plan 5A: 13-Foot Wide Accessible Guest Room
turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16 inches from side...
-
11B-406.5.3 Landings
The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing....
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices
Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters, or Other Mobility Devices
Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
Study Limitations
Third, measurements were taken on only individual users, not users traveling side-by-side or one in front of the other....
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
11B-403.5.1 Clear width
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides. 5....
-
11B-403.5.1 Clear width
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides....
-
Wheelchair Spaces (M303.2)
., wheelchair space can be entered from both the front or rear and from the side). M303.2.2 would require wheelchair spaces to be 36 inches (915 mm) wide minimum....
- Landscape Forms Inc. 35 Pitch Trash Receptacle
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
3. Medical Diagnostic Equipment
the low-height specifications for transfer surfaces, and replace them with a final specification for the low-transfer-height of medical diagnostic equipment used in the supine, prone, side-lying...
-
3. Medical Diagnostic Equipment
the low-height specifications for transfer surfaces, and replace them with a final specification for the low-transfer-height of medical diagnostic equipment used in the supine, prone, side-lying...