A restaurant has several steps at the entrance and no accessible entry is possible. Providing home delivery or some alternative service may be required....
Search Results "Side Entry"
-
Examples of meeting your “access to goods and services” obligation when physical barrier removal is not readily achievable
-
105.2.2 ASME
that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum along the back and sides...
-
105.2.2 ASME
that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum along the back and sides...
-
3. New Construction vs. Alterations
Curb ramps must be located wherever there are curbs or other barriers to entry from a pedestrian walkway or sidewalk, including any intersection where it is legal for a pedestrian to cross...
- Magnetic Switch (BE9023)
-
2. Question: What is the minimum width needed for a level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
For a conventional level boarding side passenger platform with a railing or a wall on the platform side opposite the track, the minimum platform width should be the sum of the maximum dimensions...
- Landscape Forms Inc. Gretchen Bench
- Allegion LCN 1260 Series Surface Mounted Door Control
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1010.2.13.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
1010.2.12.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-705.1.2.3 Islands or cut-through medians
pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches (51 mm) maximum on each side...
-
Overlapping Clear Floor Space
The Board has clarified that accessible lavatories are permitted to overlap clear floor space "opposite the shower compartment side where shower controls are positioned or where a seat is...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
Detailed Age Demographics
For phase 2 there is a small gap in the distribution around 25-35 years old causing the distribution on either side to be greater (Figure D2). Table D2....
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Figure 2(c) of the Guidelines is illustrating the maximum side reach range over an obstruction....
-
Room Dimensions
An important consideration is whether or not space for side transfers is provided....
-
Handrails [§405.8, §505]
Handrails [§405.8, §505] Handrails are required on both sides of ramps with a rise greater than 6”....
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
§ 38.91(d)
with the “one-car-per-train rule” at §37.93 of this title shall comply with §§38.93(e), 38.95(a) and 38.107 of this part and shall have, in new and key stations at least one door on each side...