Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
407.8.2.1 Unobstructed Side Reach
-
407.12.2.1 Unobstructed Side Reach
Where the operable part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high...
-
308.1 General
Reach ranges shall comply with 308....
-
R406.1 General
Reach ranges shall comply with R406....
-
Maximum Extent Feasible
to the Maximum Extent Feasible §36.402(c) The phrase "to the maximum extent feasible, " as used in this section, applies to the occasional case where the nature of an existing facility makes...
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
4.27.3* HEIGHT
The highest operable part of all controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
Maximum Extent Feasible
Maximum Extent Feasible....
-
11B-1002.4.3 Gaps
at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal gap shall be 3 inches (76 mm) maximum...
-
A4.27.3 HEIGHT
Fig. A6 further illustrates mandatory and advisory control mounting height provision for typical equipment. Note distinction between built-in equipment (considered real property) and...
-
11B-606.7 Sink depth
11B-606.7 Sink depth. Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis) This section proposes that, where a side approach is provided, the vertical reference plane must have a minimum...
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis) This section proposes that, where a forward reach is provided, the vertical reference plane must be, at a minimum...
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for...
-
Forward Approach
Forward Approach A maximum height of 48 inches is required for a forward reach....
-
Sales and Service Counters: ADA Standard Section 904.4
The accessible portion of the counter top shall extend the same depth as the sales or service counter top. , EXCEPTION: In alterations, when the provision of a counter complying with...
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level....
-
11B-904.4 Sales and service counters
The accessible portion of the counter top shall extend the same depth as the sales or service counter top....
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
106.5.37 Maximum Extent Feasible
106.5.37 Maximum Extent Feasible....
-
407.12.3.2.2 Knee and Toe Space
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...