5.4.2.1 Transfer Support Length Recommendation for Stretchers On Stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are...
Search Results "Examination Equipment"
-
5.4.2.1 Transfer Support Length Recommendation for Stretchers
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented...
-
5.4.3 Transfer Support Height for M301 and M302
used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated position....
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
NPRM Preamble Discussion: The Access Board is considering whether the following technical criteria would be appropriate for the location and size of transfer supports on diagnostic equipment...
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the...
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the...
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
It addresses angled supports or contoured portions of horizontal supports often provided for ergonomics or equipment design considerations....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
The Access Board is considering whether the above cross section dimensions would be appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
This clearance would allow the fingers and knuckles to clear adjacent equipment parts as they grip the support....
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302 Description: Transfer supports may contain elements to provide structural support or prevent...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings...
-
5.5.1 Armrest Provision for M302
5.5.1 Armrest Provision for M302 Description: Diagnostic equipment used by patients in a seated position such as exam chairs typically have armrests....
-
5.6.1 Stirrups Provision for M301
The Committee recommends where equipment provides stirrups, it must also provide an alternate method to support, position, and secure the patient’s legs (specifically including sufficient...
-
5.7 Lift Compatibility Recommendations
5.7 Lift Compatibility Recommendations
-
5.7.1 Lift Compatibility Clearance in Base for M301
maneuver far enough over the equipment to safely lower and raise the patient onto and off examination surfaces....
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301) The Committee recommends the equipment base provide a clearance of 39 inches wide minimum....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301) The Committee recommends the use of alternative means of access by an overhead lift in place of clearances in...
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a...
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position Description: Many people who ambulate with a disability need support to maintain...
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment The Committee recommends removing the requirement for standing supports on mammography equipment....
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations