Sec.36.304(b)(13)
(13) Rearranging toilet partitions to increase maneuvering space;...
-
§ 36.304(b)(13)
(13) Rearranging toilet partitions to increase maneuvering space;...
-
R404.3 Size
Clear spaces shall be 760 mm (2.5 ft) minimum by 1220 mm (4.0 ft) minimum....
-
M302 Diagnostic Equipment used by Patients in a Seated Position (Section-by-Section Analysis)
M302 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a seated position such as examination chairs....
-
Guest Bathrooms
The depth of a removable in-tub seat shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum. The seat shall be capable of secure placement....
-
A5.1 General
Dining counters (where there is no service) are typically found in small carry-out restaurants, bakeries, or coffee shops and may only be a narrow eating surface attached to a wall....
-
5.2.2.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
4.21.2 Size and Clearances
Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential tub/shower unit) and spaces (30" minimum...
-
1013.2 Clear Ground Space
This section requires a clear ground space 4 feet wide minimum to be provided on all usable sides of tent pads and tent platforms to enable individuals who use wheeled mobility devices to...
-
4.20.2 Floor Space
Clear floor space in front of bathtubs shall be as shown in Fig. 33....
-
4.20.2 FLOOR SPACE
Clear floor space in front of bathtubs shall be as shown in Fig. 33....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302....
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302....
-
5.2.2.1 Transfer Surface Width
The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that transfer supports must be provided for use with transfer sides on diagnostic equipment used by patients in the seated position, and that these...
-
Chapter 3: Study findings
[See subsections ...]
-
§382.127 What procedures apply to stowage of battery-powered mobility aids?
[See subsections ...]
-
Service Animals
However, in order to guarantee your seat assignment, you should be aware that, depending on whether the carrier provides advance seat assignments and the type of seating method it uses,...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....