The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
Search Results "Seating Space"
Commonly Searched Documents
-
11B-809.10.7.1 Floor space
-
Transfer Heights
For instance, level seat heights were 21.7± 1.2 inches and 22.1±1.4 inches for the first and second phases respectively....
-
T208.1 General
Non-rail vehicles shall provide passenger access routes that permit boarding and alighting, onboard circulation, and seating by passengers with disabilities....
-
Sec. 469.003(b)
(b) To the extent there is not a conflict with federal law and it is not beyond the state's regulatory power, the standards adopted under this chapter apply to a building or facility...
-
Exterior Features
Glass garage and barn doors for extra light without extra energy use. Preheated hot water from solar panels for water heater, spa, radiant heating. Greenhouses...
-
68.20(c) Facility Leased by the State
(c) A building or facility leased for use or occupied, in whole or in part, by the state under a lease or rental agreement entered into on or after January 1, 1972, is subject to the...
-
§ 38.179 Trams, and similar vehicles, and systems
[See subsections ...]
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-503.3 Access aisle
Passenger drop-off and loading zones shall provide access aisles complying with Section 11B-503 adjacent and parallel to the vehicle pull-up space....
-
I. BACKGROUND AND JURISDICTION
In addition, the United States alleges that accessible seating should have been provided in each specialty seating area that provides spectators with distinct services or amenities that...
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302. Changes in level are not permitted. ...
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302. Changes in level are not permitted....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted....
-
§ 35.138(a) General
public entity that sells tickets on a preassigned basis shall modify its policies, practices, or procedures to ensure that individuals with disabilities can purchase tickets for accessible seating...
-
Viewing Scopes [1011.2, 1011.3, and 1011.8]
Viewing scopes that can be used from a seated position provide viewing opportunities not only for seated individuals, but also for children and people of short stature....
-
707.2 Clear Floor or Ground Space
707.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...