The clear floor space shall be on an accessible route and shall extend a maximum of 19 in (485 mm) underneath the sink (see Fig. 32)....
Search Results "Expected Maximum Flight Duration"
-
4.24.5 Clear Floor Space
-
4.24.5 CLEAR FLOOR SPACE
The clear floor space shall be on an accessible route and shall extend a maximum of 19 in (485 mm) underneath the sink (see Fig. 32)....
-
§ 37.197(b)
subpart requires an entity purchasing or leasing a new OTRB to purchase or lease an accessible OTRB, OTRBs acquired through the actions listed in paragraph (a) of this section shall, to the maximum...
-
EQUIVALENT FACILITATION
Note: In determining equivalent facilitation, consideration shall be given to means that provide for the maximum independence of persons with disabilities while presenting the least risk...
-
Top Landings
The proposed rule specified that side flares of 1:12 maximum must be provided when space at the top of curb ramps is less than 48 inches long. This specification has been removed....
-
214 and 611 Washing Machines and Clothes Dryers
An exception will permit the maximum height for the tops of these machines to be 2 inches higher than the general requirement for maximum high reach over an obstruction....
-
Elevated Accessible Routes
inch (915 mm) clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate features in the composite structure 12-inch (305 mm) rise maximum...
-
Play Tables
17 inches (430 mm) deep minimum Play tables designed primarily for children under 5 years old may provide a parallel approach instead of knee clearance if the rim is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not steeper than 1:8 3...
-
11B-604 Water closets and toilet compartments
INTERPRETATION Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum slope of ¼ inch per foot to a drain (refer to CPC Section 408.5 and CBC Section...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope¹ Maximum Rise Steeper than 1:10 but not...
-
711.3.1 Through penetrations
space between the penetrating item and the fire-resistance- rated wall shall be permitted to be protected as follows: In concrete or masonry walls where the penetrating item is a maximum...
-
405.2 Slope
Table 405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities Slope1 Maximum Rise Steeper than 1:10 but not...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
608.6 Shower Spray Unit and Water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum...
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
- Midmark 641 Barrier-Free® Power Procedures Chair
- Hadrian Inc. Gladiator Athletic Lockers
- AquaTrek2 ADA Wading Pool Ramp
-
Outdoor Constructed Features
Individuals who use wheeled mobility devices are not expected to transfer from the devices when using outdoor rinsing showers and do need grab bars for this purpose....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....