Error/Omission: Objects protrude into circulation paths from the side or from posts. Objects that overhang circulation paths do not provide clear headroom....
Search Results "Latch Side Clearance"
Commonly Searched Documents
-
Circulation Paths
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
UDI
The starting clearance for each trial was the minimum clearance of the Canadian CSA B651-95 Standard....
- Stanley Access Technologies Dura-Care 7000 Manual Door System
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
305.7.1 Forward Approach
Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach...
-
305.7.2 Parallel Approach
Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
- PEMKO 5 9/16" Thermal Barrier Threshold No. 273x292-FGPK
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
T213.3 Armrests at Aisle Seats on Over-the-Road Buses
Where armrests are provided on the aisle side of seats on over-the-road buses, folding or removable armrests shall be provided on the aisle side of at least 50 percent of aisle seats....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
- Hager Companies Round Wrought Door Pull 4
- Hager Companies Round Wrought Door Pull 3
- Hager Companies Round Offset Pull 11
- Hager Companies Round Wrought Door Pull 12
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
The proposed provision requires standing supports be provided on each side of the standing surface....
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
The Committee recommends measuring the transfer surface from the center-point of each side of the transfer surface....
-
8.2 READING AND STUDY AREAS
Clearances between fixed accessible tables and study carrels shall comply with 4.3....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
Accessible Presentation / Speaker’s Platform - Talk Show Style
Side tables should be provided (for water, notes, or other materials) for each guest. Individuals who use wheelchairs or scooters may need a higher side table than other guests....