Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
Search Results "Curb Ramp Top Landing"
-
11B-705.1.1.1 Dome size
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
Cane detectable barriers at stand pipes in stair ways
Does anyone have photos of cane detectable barriers that you have seen/used around the stand pipes and fire risers which are installed in corner landings of stair wells?...
-
Gaps: ADA Standard Section 1002.4.3
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
1007.7.1 Level of exit discharge
discharge does not include an accessible route from an exit located on a level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on the exterior landing...
-
USE ZONE
immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land...
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
USE ZONE
immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land...
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground. [ECTCR UFAS 5.2]...
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
M305.3.2.1 Horizontal Position
The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface....
-
5.8.2.1 Height of Breast Platform At Time of Measurement
All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
903.5 Height
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
1132A.4, Item 1
Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change...
-
[A] PUBLIC WAY
A street, alley or other parcel of land open to the outside air leading to a street, that has been deeded, dedicated or otherwise permanently appropriated to the public for public use and...
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. ...
-
1132A.4, Item 1
Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change...