Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
Search Results "Shall"
Commonly Searched Documents
-
11B-707.6.3.1 Contrast
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
217 Telephones
In addition, 25 percent, but never less than one, of all other public telephones provided shall be equipped with a volume control and shall be dispersed among all types of public telephones...
-
§ 38.77(b)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
11B-411.1.1 Floor designations
Floor designations shall be "one" (1) or "zero" (0) at the main entry level and shall increase by one for each successive higher story or level....
-
§ 38.155(a)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-411.1.1 Floor designations
Floor designations shall be "one" (1) or "zero" (0) at the main entry level and shall increase by one for each successive higher story or level....
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
F210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1....
-
210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1....
-
A. Arena Assembly Seating:
At least one (1) companion seat (“Companion Seat”) shall be provided for each Wheelchair Seat. ...
-
Employee for ADA Compliance
The Village shall identify the designated individual to the United States for approval, which shall not be unreasonably withheld. ...
-
Employee for ADA Compliance
The City shall identify the designated individual to the United States for approval, which shall not be unreasonably withheld. ...
-
Employee for ADA Compliance
The City shall identify the designated individual to the United States for approval, which shall not be unreasonably withheld....
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers and sanitary napkin disposal units shall comply with Section 11B-604.7....
-
11B-206.6 Elevators
Elevators provided for passengers shall comply with Section 11B-407. Where multiple elevators are provided, each elevator shall comply with Section 11B-407....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
11B-407.2.1.2 Size and shape
Call buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
604.9.6 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
410.6 Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum....