Electrical or communication receptacles serving a dedicated use shall not be required to comply with 309. 3....
Search Results "Shall"
Commonly Searched Documents
-
205.1 General
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.9 Emergency Communication
Emergency two-way communication systems shall comply with 308. Tactile symbols and characters shall be provided adjacent to the device and shall comply with 703.2....
-
4.18.4 FLUSH CONTROLS
Flush controls shall be hand operated or automatic, and shall comply with 4.27.4, and shall be mounted no more than 44 in (1120 mm) above the floor....
-
604.9.5 Flush Controls
Flush controls shall be hand operated or automatic....
-
604.9.5 Flush Controls
Flush controls shall be hand operated or automatic....
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
-
211.2 Minimum Number
No fewer than two drinking fountains shall be provided. One drinking fountain shall comply with 602.1 through 602.6 and one drinking fountain shall comply with 602.7....
-
810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
-
407.4.7.2 Keypads
Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot....
-
4.7.2 SLOPE
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11....
-
Guest Bathrooms
The depth of a removable in-tub seat shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum. The seat shall be capable of secure placement....
-
11B-707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
-
T302.4 Surface Discontinuities
Surface discontinuities shall be ½ inch (13 mm) high maximum and shall be beveled with a slope not steeper than 1:2. EXCEPTIONS: 1....
-
4.7.2 Slope
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11....
-
4.10.5 RAISED CHARACTERS ON HOISTWAY ENTRANCES
All elevator hoistway entrances shall have raised floor designations provided on both jambs. The centerline of the characters shall be 60 in (1525 mm) from the floor....
-
4.30.4* RAISED CHARACTERS OR SYMBOLS
Letters and numbers on signs shall be raised 1/32 in (0.8 mm) minimum and shall be sans serif characters....
-
§ 38.159(c)(2) Ramp surface
The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch (6.5 mm) high; shall have a clear width of 30 inches (760 mm);...
-
§ 38.37(b)
(b) Controls required by paragraph (a) of this section shall be mounted no higher than 48 inches and no lower than 15 inches above the floor, shall be operable with one hand and shall not...
-
11B-707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
-
4.18.4 Flush Controls
Flush controls shall be hand operated or automatic, and shall comply with 4.27.4, and shall be mounted no more than 44 in (1120 mm) above the finish floor....