Where the running slope (grade) of a segment of a trail is steeper than 1:20 (5 percent), the maximum length of the segment shall be in accordance with Table 7.4.3.1, and a resting interval...
Search Results "Maximum Dimension"
Commonly Searched Documents
-
7.4.3.1 Running Slope (Grade)
-
Common Requirements (R304.5) (Section-by-Section Analysis)
A maximum cross slope of 2 percent is specified for curb ramps, blended transitions, and turning spaces....
- AquaTrek2 ADA Ladder System
-
§ 36.403(a)(1)
(1) An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure that, to the maximum extent...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Cross Slope
Cross Slope The cross slopes of gangways, transition plates and floating piers that are part of an accessible route must be designed and constructed not to exceed a maximum of 2 percent...
-
Dispersion
To provide anglers with disabilities similar opportunities, the accessible 34-inch maximum railing must be located in a variety of places on the pier or platform to offer a variety of locations...
-
403.5.1 Clear Width
EXCEPTION: The clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated by...
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum...
-
Toilet Rooms-Banquet Area
The force required to push or pull open the doors to the women's and men's toilet rooms designated as accessible is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
1009.5.4 Transfer Steps
Transfer step height shall be 8 inches (205 mm) maximum....
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals of 61 meters (200 feet) maximum...
-
R407.2 Running Slope
Ramp runs shall have a running slope between 5 percent minimum and 8.3 percent maximum. Advisory R407.2 Running Slope....
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers...
-
12142(c)(1)(B)
for 5 years or more, which purchase or lease occurs after such 30th day and during the period in which the usable life is extended; unless, after remanufacture, the vehicle is, to the maximum...
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
10.3.1(2)
All accessible entrances shall, to the maximum extent practicable, coincide with those used by the majority of the general public....
-
4.7.5 SIDES OF CURB RAMPS
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, then it shall have flared sides; the maximum slope of the...
-
Post-Mounted Objects [§307.3]
Objects with leading edges 27” maximum or above 80” can protrude any amount from posts or pylons....
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
§ 38.159(b)(10) Platform movement
The maximum platform horizontal and vertical acceleration when occupied shall be 0.3g....
-
§ 38.153(c)(1)
The clear width may be reduced by a maximum of 4 inches (100 mm) by protrusions of hinges or other operating mechanisms....