Specifications for benches address clear floor or ground space (903.2), size (903.3), back support (903.4), height (903.5), structural strength (903.6), and slip resistance in wet locations...
Search Results "Adjustable Height Counter"
Commonly Searched Documents
-
903 Benches
-
III. Proposed alternative mechanisms to enhance patient access to diagnostic imaging equipment
For example, in a CT/PET system, the patient support surface is located on top of a transporter, which adds to the height of the transport surface....
-
1. Abdomen depth (AD)
., knee clearance height, foot clearance height or depth). Table 1 and Figure 1 show the percentiles and maximum observed values for male and female wheelchair users....
-
1134A.7 Water closets
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....
-
1011.3 Operable Parts
This section requires operable parts of outdoor constructed features to comply with the technical requirements for the height of operable parts in 309.3 of the Architectural Barriers Act...
-
302.2 Carpet
Pile height shall be ½ inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....
-
Tread Obstacles [1017.5]
The limit on the height of tread obstacles on trails, passing spaces, and resting intervals is based on the surface material used....
-
1003.2.12.2 Opening limitations
Open guards shall have balusters or ornamental patterns such that a 4-inch-diameter (102 mm) sphere cannot pass through any opening up to a height of 34 inches (864 mm)....
-
302.2 Carpet
Pile height shall be ½ inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....
-
1134A.7, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....
-
4.34.3(2)(b) Reach Depth More Than 10 in
vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion of the automated teller machine or surround is more than 10 in (255 mm), the maximum height...
-
1134A.7, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....
-
11B-504.8 Floor identification
11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings two or more stories in height...
-
1.17 Unobstructed view
Order, shall mean and refer to a view to the screen that is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance over average height...
-
Visual Display Screens
Section 707.7 addresses visual display screens and provides specifications for the screen height and the legibility of visual characters....
-
Sec.36.402(b)(1)
rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
D4. Door Clearance
[ADA Stds 4.13.6, figure 25] Note: The maximum threshold height is 1/2 inch for new construction....
-
Mats
Where used, it is recommended that they meet the pile height and trim requirements for fixed carpeting, have firm tapered edges for smooth transitions, be firm enough to minimize buckling...
-
Additions [§202.2]
Additions [§202.2] Projects that increase, expand, or extend a facility’s gross floor area or height of a facility are considered additions (as defined in §106.5) and must comply with...
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
- U.N. Convention on the Rights of Persons with Disabilities (CRPD)
- Little People of America