Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
Search Results "Maximum Reach Depth"
-
11B-705.1.2.2.1 Perpendicular curb ramps
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
11B-604.9.6 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
- Council of Citizens with Low Vision International (CCLVI)
-
M101.5 Dimensions
Dimensions that are not stated as “maximum” or “minimum” are absolute....
-
M307.4 Operating Force
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum....
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum....
-
R407.3 Cross Slope
The cross slope of ramp runs shall be 2 percent maximum....
-
R304.4.1 Running Slope
The running slope of blended transitions shall be 5 percent maximum....
-
B2. Slope
Is the vehicle space relatively level (2% maximum slope in all directions)? Yes _____ No _____...
-
M307.4 Operating Force
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum....
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum....
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
§8.23(b)(1)
(1) Subject to paragraph (b)(2) of this section, alterations to dwelling units in a multifamily housing project (including public housing) shall, to the maximum extent feasible, be made...
-
11B-604.7 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 _|Operation|_ and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...