extends to those elements used to enter the commercial facility, including the homeowner's front sidewalk, if any, the door or entryway, and hallways; and those portions of the residence, interior...
Search Results "Interior Route"
-
Sec.36.401(b)(2)
-
III- 7.4400 Signage
Requirements for exterior signs are essentially the same as those for interior signs (see §4.1.3(b) below)....
-
11B-502.6.3 Location
Signs may also be permanently posted on a wall at the interior end of the parking space....
-
§ 36.401(b)(2)
extends to those elements used to enter the commercial facility, including the homeowner´s front sidewalk, if any, the door or entryway, and hallways; and those portions of the residence, interior...
-
11B-502.6.3 Location
Signs may also be permanently posted on a wall at the interior end of the parking space....
-
11B-502.6.3 Location
Signs may also be permanently posted on a wall at the interior end of the parking space....
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
11B-1008.2.4.1 Ground level
At ground level, the clear width of accessible routes shall be 60 inches (1524 mm) minimum....
-
11B-233.3.1.2.6.3 Test number two, site analysis test
For a site having multiple buildings, or a site with a single building with multiple entrances, it is not required to provide a building entrance on an accessible route to all ground floor...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
For a site having multiple buildings, or a site with a single building with multiple entrances, it is not required to provide a building entrance on an accessible route to all ground floor...
-
1007.6.2 Separation
Exception: Areas of refuge located within an enclosure for exit access stairways or interior exit stairways....
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
-
4.3.11.1(2)
Openings to the interior of the building located within 20 feet (6 m) of the area of rescue assistance shall be protected with fire assemblies having a three-fourths hour fire protection...
-
Contrast
Contrast Interior applications require that the warning feature provide contrast in resilience or in sound when sensed with a cane....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
11B-228.2 Mail boxes
Where mail boxes are provided in an interior location, at least 5 percent, but no fewer than one, of each type shall comply with Section 11B-309....
-
Restrooms Main Lobby
The force required to push or pull open the interior hinged doors to the restroom vestibule door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...