Software Worry-Free Maintenance 1 Year Standard Warranty Embossing Print speed: Up to 50 CPS Printing Mode: Single-sided Tactile Resolution: 20 DPI Tactile Graphic Dot Heights...
Search Results "Closer Height"
- ViewPlus Technologies VP Cub Braille Printer
-
3.3.16 Door Use
The additional effort required of door 3 for the “Opening” task was expected because door 3 had a mechanical closer that had a resistance of 7‒8 lb-f....
- Hill-Rom Uno™ 102 Patient Lift
- Da-Lite Global Product & Manufacturing Center ADA Lectern
- Garaventa Elvoron CPL Vertical Platform Lift
- Sony Entertainment Access Glasses
- Boolee Voting Booth
- Whitehall Mfg. Ligature Resistant Bariatric Stainless Steel Basin
- Whitehall Mfg. WH2142W2 Ligature-Resistant Toilet Wall Supply On-Floor Wall Waste
-
Gates and Barriers
ABAAS, section 404.2.3 also contains allowances for projections of closers and stops that aren't likely to apply to trail barriers or gates....
-
11B-604.3.2 Overlap
Section 408.5 and CBC Section 11B-608.9), and a threshold, between the shower receptor and the fixture clearance provided outside the shower (CBC Section 11B-608.2.2.1) with a maximum height...
-
11B-604.3.2 Overlap
Section 408.5 and CBC Section 11B-608.9), and a threshold, between the shower receptor and the fixture clearance provided outside the shower (CBC Section 11B-608.2.2.1) with a maximum height...
-
11B-233.3.1.2.6.5 Additional requirements.
Water closet seat height complying with Section 11B-809.10.7.4. 7. Electrical receptacles, switches and controls complying with Section 11B-809.12. 8....
-
Shelves, Sales and Service Counters, and Check-Out Aisles
However, shelves may be of any height since they are not subject to the ADA’s reach range requirements....
-
Keypad Buttons
included a requirement that the characters provided on buttons comply with visual characteristics specified in section 703.5, which covers finish and contrast, character proportion and height...
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
3.1 Canton Tinseltown 15, 4720 Mega Street NW North Canton, Ohio
- In Auditorium 5, the four (4) wheelchair spaces shall be raised six inches in height at their current location....
-
Accessible Play Components
These play components must also comply with other accessibility requirements, including specifications for clear floor space and seat heights (where provided)....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
1115B.4.4.5
This unit shall be mounted such that the top of the mounting bracket is at a maximum height of 48 inches (1219 mm) above the shower floor....
-
604.5 Grab Bars
must be sufficient to permit the installation of rear and side wall grab bars that fully meet all accessibility requirements including, but not limited to, required length, installation height...
-
302.2 Carpet
Pile height shall be 1/2 inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....
-
704.9 Vertical separation of openings
Exceptions: This section shall not apply to buildings that are three stories or less in height....