11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
-
11B-604 Water closets and toilet compartments
[See subsections ...]
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1009.7 Stair treads and risers
1009.7 Stair treads and risers. ...
-
1011.5 Stair treads and risers
...
-
1011.5 Stair treads and risers
...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
407.12.2.1 Unobstructed Side Reach (Section-by-Section Analysis)
Although existing 508 Standards § 1194.25 (j)(2) permits a maximum reach height of 54 inches, it contains the same minimum height (15 inches) and 10-inch reach depth....
-
602.6 Water Flow
602.6 Water Flow. The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
1008.2.3 Water Play Components
1008.2.3 Water Play Components. Accessible routes serving water play components shall be permitted to use the exceptions in 1008.2.3. EXCEPTIONS: 1....
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
1008.2.3 Water Play Components
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
-
1008.2.3 Water Play Components
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section....
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section....
-
606.4 Faucets and Water Spray Units
606.4 Faucets and Water Spray Units The final rule revises this section to require a water spray unit to be provided at the kitchen sink in emergency transportable housing units required...
-
4.34.3(2)(b) Reach Depth More Than 10 in
(b) Reach Depth More Than 10 in (255 mm)....
-
Side Reach [§308.3]
The maximum reach depth for this range is 10” measured from the available clear floor space....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. The back...
- 604.3.1 Water Closet Clear Floor Space
-
4.15.3 Spout Location
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
-
4.15.3 SPOUT LOCATION
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
- Delta Toilet with FlushIQ Technology