Private residence elevator cars shall comply with 409.4....
Search Results "Private Building"
-
409.4 Elevator Cars
-
409.4 Elevator Cars
Private residence elevator cars shall comply with 409.4....
-
11B-409.4 Elevator cars
Private residence elevator cars shall comply with Section 11B-409.4....
-
11B-409.4 Elevator cars
Private residence elevator cars shall comply with Section 11B-409.4....
-
11B-409.4 Elevator cars
Private residence elevator cars shall comply with Section 11B-409.4....
-
409.4 Elevator Cars
Private residence elevator cars shall comply with 409.4....
-
§ 36.309(b)(1)
(1) Any private entity offering an examination covered by this section must assure that –...
-
Sec.36.309(b)(1)
(1) Any private entity offering an examination covered by this section must assure that --...
-
§104.39 Private education.
[45 FR 30936, May 9, 1980, as amended at 65 FR 68055, Nov. 13, 2000]
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
11B-203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 11B-203....
-
Excerpts from 2003 INTERNATIONAL BUILDING CODE®
COPYRIGHT© 2003 by INTERNATIONAL CODE COUNCIL, INC.
-
Excerpts from 2001 INTERNATIONAL BUILDING CODE®
[See subsections ...]
-
Grab Bars: ADA Standard Section 607.4
Section 607.4 covers the current ADA Standards for bathtub grab bars.
-
4.2.4 Height of Fire-Building Surface
The fire-building surface within a fire ring shall be at least 9 inches (230 mm) above the floor or ground....
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.