Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high. The...
Search Results "Path"
-
11B-307.4 Vertical clearance
-
206.2.4 Spaces and Elements
accessible route shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility which are otherwise connected by a circulation path...
-
203.9 Employee Work Areas
Specifically, employee work areas must meet accessibility requirements for: circulation paths for common use within the area, except for those that are an integral part of equipment...
-
10.4.1(2)
(2) The circulation path, including an accessible entrance and an accessible route, for persons with disabilities shall, to the maximum extent practicable, coincide with the circulation...
-
Wall-Mounted Objects
Proper cane and service animal techniques allow people to walk along a corridor or path without bumping into walls....
-
307.2 Protrusion Limits
leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path...
-
11B-307.2 Protrusion limits
leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into the circulation path...
-
11B-307.2 Protrusion limits
leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into the circulation path...
-
307.2 Protrusion Limits
leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path...
-
11B-307.2 Protrusion limits
leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into the circulation path...
-
307.2 Protrusion Limits
leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path...
-
206.2.8 Employee Work Areas
Common use circulation paths within employee work areas shall comply with 402. EXCEPTIONS: 1....
-
206.2.8 Employee Work Areas
Common use circulation paths within employee work areas shall comply with 402. EXCEPTIONS: 1....
-
When an addition increases the number of stories or square footage beyond the maximum permitted by the exception, is an accessible route between stories required?
Also, if the addition includes a primary function area, an accessible path of travel to the primary function area is required, including where it involves travel between stories or levels...
- Envirobond is Self-Healing
- Organic-Lock: The Self-Healing Organic Binder
-
TechniSoil G3® Pathway Stabilizer Video
Requires the Registered User plan or above. Login!
- Envirobond Helps Avoid Surface Staining
- Envirobond Deters Weeds
-
Re: § 36.403(d) Landlord/tenant
Tenant space alterations may trigger path of travel obligations for the landlord....
-
§ 35.151(b)(4)(iii)
(iii) Disproportionality.
-
§ 35.151(b)(4)(v) Series of smaller alterations
(v) Series of smaller alterations.
-
Scoping [4.1.2(3), 4.1.3(2)]
Requirements for protruding objects apply to all circulation routes, including both accessible and inaccessible routes and include corridors, walks, courtyards, stairways, and areas...