Areas of refuge shall be provided with a two-way communication system between the area of refuge and a central control point....
Search Results "Hybrid Surface System"
Commonly Searched Documents
-
1007.6.3 Two-way communication
-
1003.2.13.5.3 Two-way communication
Areas of refuge shall be provided with a two-way communication system between the area of refuge and a central control point....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward...
-
1016.7 Slopes
The slopes of outdoor recreation access routes shall comply with 1016.7.
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward...
-
Summary of Recommendations
Summary of Recommendations
-
R302.6 Cross Slope
R302.6 Cross Slope. Except as provided in R302.6.1 and R302.6.2, the cross slope of pedestrian access routes shall be 2 percent maximum. Advisory R302.6 Cross Slope. The cross...
-
Effect of Handhelds on Transfer Height
Participant preference for grab bars and backrest heights for protocols B through E are shown in Table 17. For all protocols the tall grab bars were preferred. For protocol C the...
-
A. Accessible Counters
A. In each restaurant or other food service establishment on this site, are at least 5% of each type of fixed table or a portion of eating counters (i.e.: where no direct service is...
-
1. & 2. Sidewalk Slope
1. ...do the sidewalks have cross slopes (i.e.: slopes tilting side to side) less than 1:50 (critical dimension of ´" or less) [sic] so persons who use wheelchairs can conveniently...
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum...
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum.
-
4.8.1* General
Any part of an accessible route with a slope greater than 1:20 shall be considered a ramp and shall comply with 4.8.
-
7.4.11.1 Clear Space
Trailhead signs shall be located centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) minimum clear floor or ground space. The clear space shall not overlap the trail...
-
5.1* General
Except as specified or modified in this section, restaurants and cafeterias shall comply with the requirements of 4.1 to 4.35. Where fixed tables (or dining counters where food is...
-
Spa
Plants throughout to remove contaminants and increase oxygen levels Weights, treadmill, and wind trainer, and ceiling mounted TV in a beautiful space (not hidden in the...
-
4.8.1* GENERAL
Any part of an accessible route with a slope greater than 1:20 shall be considered a ramp and shall comply with 4.8.
-
1017.7 Slopes
This section contains technical requirements for the maximum running slope and segment length (1017.7.1) and cross slope (1017.7.2) of trails.
-
3.1.3 Slope of Vehicle Parking Spurs
The slope of parking spurs shall comply with applicable provisions of section 3.1.3.
-
5.1 GENERAL
In addition to the requirements of 4.1 to 4.33, the design of at least 5 percent of all fixed seating or tables in a restaurant or cafeteria shall comply with 4.32. Access aisles...
-
1017.7.1 Maximum Running Slope and Segment Length
This section requires that not more than 30 percent of the total length of a trail have a running slope steeper than 1:12 (8.33%), and that the running slope of any segment of a...
-
1016.7 Slopes
The slopes of outdoor recreation access routes shall comply with 1016.7.