Allow 3/8" door clearance. ADA Compliant when butted to carpet or tile....
Search Results "Handrail Clearance"
Commonly Searched Documents
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-T
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-T
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
- Populas Accella Adjustable Activity / Computer Workstation
- Pilot Rock UT Series Side Accessible Picnic Table Using Recycled Plastic
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
- Lift-U® LU12 Step/Platform Onboard Lift
-
Transit Shelters (R308.2) (Section-by-Section Analysis)
A circular space is permitted to include knee and toe clearance. A T-shaped space is permitted to include knee and toe clearance only at the end of either the base or one arm....
-
RECOMMENDATIONS
32.7 m Vertical alignment-crest 49.8 m Recumbent bicyclists 46.7 m Refuge islands 2.5 m Bicyclists with trailers 3.0 m Signal clearance...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Chapter 3: Building Blocks
These requirements address floor and ground surfaces (302), changes in level (303), wheelchair turning space (304), clear floor or ground space (305), knee and toe clearance (306), protruding...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
A4.31.9 Text Telephones
text telephone which is not a single integrated text telephone pay phone unit will require a shelf large enough (10 in (255mm) wide by 10 in (255 mm) deep with a 6 in (150 mm) vertical clearance...
-
Clear Floor Space [4.35.2]
Benches can overlap turning space where clearance (9 inches minimum) is available for toes....
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
Re: Lavatories Adjacent to Partitions
I would add that the California text does not specifically require a 'clearance' related to that 18" that we would theoretically be obligated to keep clear....
-
Re: Stair widths
The reason for the 48 inch requirement between handrails here is because people with mobility issues may require assistance down or up the stairs. ...
- Corbin Russwin Inc. DC46900 Series Safeguard Door Closers
- Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
- Rockwood Manufacturing Company 110 x 70B Pull Plate 8" CTC Pull 3-1/2" x 15" Plate
- Rockwood Manufacturing Company 102 x 70B - Pull Plate 5-1/2" CTC Pull 3-1/2" x 15" Plate
- Populas Infinity Workstation
-
Changes in Level and Horizontal Gaps
Negotiating such a step can be difficult for ambulatory passengers, especially since handrails are usually not available....