Exception: The sloping portions of handrails serving stairs and ramps shall not be required to comply with Section 11B-307.3....
Search Results "Handrail Clearance"
-
11B-307.3 Post-mounted objects
-
Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
11B-307.3 Post-mounted objects
Exception: The sloping portions of handrails serving stairs and ramps shall not be required to comply with Section 11B-307.3. ...
-
11B-307.3 Post-mounted objects
Exception: The sloping portions of handrails serving stairs and ramps shall not be required to comply with Section 11B-307.3....
-
307.3 Post-Mounted Objects
EXCEPTION: The sloping portions of handrails serving stairs and ramps shall not be required to comply with 307.3....
-
[2010 ADAS] 105.2.4 ICC/IBC
An exception addresses the height of the railings, guards, or handrails where a fishing pier or platform is required to include a guard, railing, or handrail higher than 34 inches (865 mm...
-
F105.2.4 ICC/IBC
An exception addresses the height of the railings, guards, or handrails where a fishing pier or platform is required to include a guard, railing, or handrail higher than 34 inches (865 mm...
-
1013.3 Height
For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, where the top of the guard also serves as a handrail on the open sides of stairs, the top...
-
1015.3 Height
For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, where the top of the guard also serves as a handrail on the open sides of stairs, the top...
-
ICC/IBC
An exception addresses the height of the railings, guards, or handrails where a fishing pier or platform is required to include a guard, railing, or handrail higher than 34 inches (865 mm...
-
105.2.4 ICC/IBC
An exception addresses the height of the railings, guards, or handrails where a fishing pier or platform is required to include a guard, railing, or handrail higher than 34 inches (865 mm...
-
105.2.4 ICC/IBC
An exception addresses the height of the railings, guards, or handrails where a fishing pier or platform is required to include a guard, railing, or handrail higher than 34 inches (865 mm...
-
4.2.5* Forward Reach
If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b)....
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(2) If a cabinet is provided under the lavatory in adaptable bathrooms, then it shall be removable to provide the clearances specified in 4.22.6....
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
- Don-Jo Mfg., Inc. Pull Plate 7011
- Bobrick MatrixSeries Seat-Cover Dispenser B-5221
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
1.17 Unobstructed view
purposes of this Consent Order, shall mean and refer to a view to the screen that is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance...
-
7. Lavatory
Is the lavatory (wash basin) in each accessible guestroom bathroom no more than 34" high with at least 29" high clearance under the front edge to allow persons who use wheelchairs to pull...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....