Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
Search Results "Ground Surface"
-
11B-803.3 Door swing
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
- Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach – Drawing from the U.S. Access Board
- Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach – Drawing from the U.S. Access Board
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum....
-
M305.3.2 Vertical Position
vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high maximum above the standing surface...
-
GRADE (Adjacent Ground Elevation)
[DSA-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property line is...
-
GRADE (Adjacent Ground Elevation)
[DSA-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property line is...
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
clear ground space (figure 23)....
-
Play Areas
Word Fillable Form (0.4MB) Word Non-Fillable Form (0.3MB) PDF Non-Fillable Form (0.3MB)
-
18 Inch Low Height
between the wheeled mobility device and the piece of medical equipment increased and cautioned against speculating that height differences between the wheeled mobility device and transfer surface...
- GameTime Roller Slide
- GameTime Adaptive Swing Seat
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
Figure M1: Overview of M301 Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position
[See subsections ...]
-
5.3.2.1 Transfer Sides Recommendation for Stretchers
5.3.2.1 Transfer Sides Recommendation for Stretchers On stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone...
-
Other Counters/ Teller Windows [7.2(2)]
Windows [7.2(2)] Alternatives to 36-inch high counters (lowered portions, folding shelves) are recognized since other design considerations (security, use by standees) may make a higher surface...
-
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position.
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests. The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed...
-
Addendum E: Comparison of participants tested at the National Disabled Veterans Winter Sports Clinic (NDVWSC) compared to the participants tested at the Human Engineering Research Laboratories and Hiram G. Andrews Center
At the time this addendum was composed, there were 31 participants enrolled in the phase 2 study at HERL (27 men and 4 women). This group of subjects was compared to all the...
-
Kitchen Cabinets
42” a.f.f. (above finished floor) wall-mounted cabinets and counters for tall people. With a remodel, they can be lowered to 32” a.f.f. for wheelchair users 10”...
-
9.2* POST OFFICE LOBBIES
Where writing desks or tables are provided, a minimum of at least one writing desk or table that complies with 4.32 must be provided. Clear passageways in front of customer service...
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance (§505.5, §505.7)