establish minimum technical criteria for medical diagnostic equipment used in (or in conjunction with) physician's offices, clinics, emergency rooms, hospitals, and other medical settings.1...
Search Results "Enhanced 9-1-1"
-
BACKGROUND
- Gamco Partition Mounted Dual-Sided Multi-Roll Toilet Tissue Dispenser - TTD-7
-
11B-809.10.5.4 Bathtub enclosures
When glass is used, it shall be 1/8 inch (3.2 mm) thick minimum when fully tempered, or 1/4 inch (6.4 mm) thick minimum when laminated, and shall pass the test requirements of this part,...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-809.10.5.4 Bathtub enclosures
When glass is used, it shall be 1/8 inch (3.2 mm) thick minimum when fully tempered, or 1/4 inch (6.4 mm) thick minimum when laminated, and shall pass the test requirements of this part,...
-
11B-1007.2 Accessible routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (813 mm) minimum....
-
11B-1007.2 Accessible routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (813 mm) minimum....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
floor units in non-elevator buildings shall be adaptable and on an accessible route unless an accessible route to the common (lobby) entrance is not required as determined by Test No. 1,...
- Seton Economy Braille Signs - Men's Restroom with ISA
- Seton Economy Braille Signs - Women's Restroom with ISA
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3. [2010 ADAS] 702.1 General. ...
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3. [2010 ADAS] 702.1 General....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
11B-205.1 General
Exceptions: 1. Operable parts that are intended for use only by service or maintenance personnel shall not be required to comply with Section 11B-309. 2....
-
11B-205.1 General
Exceptions: 1. Operable parts that are intended for use only by service or maintenance personnel shall not be required to comply with Section 11B-309. 2....
-
1008.4.2 Clear Floor or Ground Space
This will enhance the ability of children with disabilities to independently use the play component....
-
1008.4.2 Clear Floor or Ground Space
This will enhance the ability of children with disabilities to independently use the play component....
-
1008.4.2 Clear Floor or Ground Space
This will enhance the ability of children with disabilities to independently use the play component....
-
11B-1008.4.2 Clear floor or ground space
This will enhance the ability of children with disabilities to independently use the play component....
-
11B-1008.4.2 Clear floor or ground space
This will enhance the ability of children with disabilities to independently use the play component....
- Gamco Recessed Multi-Roll Toilet Tissue Dispenser - TTD-6
- Seton Flexible Bollard Sign Post Systems
-
11B-405.7.1 Slope
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....