ADA Actuators – 1.5" x 4.75" Jamb Actuator ISA Logo Only Features: - Hard wired and wireless (hard wired standard) - Beveled edges - Graphics embossed onto the faceplate for durability...
Search Results "Platform Edge"
- Hager Companies 1.5" x 4.75" Jamb Actuator 2-659-0176
- Nora Systems, Inc. Norament Round Stairtreads
- Hager Companies 1.5" x 4.75" Jamb Actuator 2-659-0175
-
C205.2 WCAG Conformance (Section-by-Section Analysis)
C205.2 WCAG Conformance (Section-by-Section Analysis) This section proposes that specified components of covered ICT—namely, user interface components, platform content, and application...
-
Meeting Room Layouts and Considerations
Additional considerations, such as audio/visual tools and using a speaker’s platform, are also included....
-
Examples of access:
A wheelchair user can roll onto the scale platform. A patient with poor balance can walk onto the scale or get weighed sitting in a chair....
-
Transfer Surface (M301.2 and M302.2)
Depending on the configuration of the equipment, the transfer surface may coincide with the seat area of an examination chair, or occupy only a portion of an examination table or imaging bed platform...
- American Association on Intellectual and Developmental Disabilities
-
307.3 Post-Mounted Objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
M303.2.4.2.2 Height
minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm) minimum at 27 inches (685 mm) above the floor measured from the leading edge...
-
5.3.3 Transfer Sides Recommendations for M302
The provisions result in the transfer surface being located at a corner of the equipment and the two transfer sides adjoining at the edges of the equipment....
-
Rough Form and Foundation Inspection
Verify no abrupt changes in level will exceed ½” in the path of travel or 4” drop offs along edges. 11B-303.5 Verify forms include guardrail and handrail...
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
Landings [4.8.4]
For example, runs should be aligned along the outside landing edge, as in the case of ramps with a 90 degree turn, so that a wider turn is permitted....
-
Rough Form and Foundation Inspection
Verify no abrupt changes in level will exceed ½” in the path of travel or 4” drop offs along edges. 11B-303.5 Verify forms include guardrail and handrail...
-
Vertical Clearance [§307.4]
Barriers must have leading edges no higher than 27” so that they are within cane sweep. Fixed planters, benches, and other elements can be used instead of guardrails....
-
§ 38.23(c)(8) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.95(c)(8) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
§ 38.83(c)(8) Handrails
The handrail shall have a cross- sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have “eased” edges with corner radii of not less...
-
§ 38.125(c)(8) Handrails
The handrail shall have a cross-sectional diameter between 1 1/4 inches and 1 1/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
11B-805 Medical care and long-term care facilities
686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge...
-
Fire Rings, Grills, Fireplaces, and Woodstoves [1011.2, 1011.3, and 1011.5]
Some custom-built fire rings and fireplaces may have a raised edge or wall around the fire-building area, perhaps built out of bricks or mortared stone....