Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. Advisory 903.4 Back Support....
Search Results "Platform Edge"
-
903.4 Back Support
-
903.4 Back Support
Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. Advisory 903.4 Back Support....
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
An obstructed forward reach, for purposes of this section, occurs when the operable part is located behind the leading edge of the maximum protrusion within the length of the vertical reference...
-
307.3 Post-Mounted Objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
R402.3 Post-Mounted Objects
Where objects are mounted between posts or pylons and the clear distance between the posts or pylons is greater than 305mm (1.0 ft), the lowest edge of the object shall be 685 mm (2.25 ft...
-
Accessible - Changes in Level
Accessible - Changes in Level: Changes in level up to 1/4" may be vertical and without edge treatment....
-
1134A.5, Item 1
The edge of the clear floor space shall be flush with the control wall surface....
-
11B-307.3 Post-mounted objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
11B-307.3 Post-mounted objects
Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches (305 mm), the lowest edge of such sign or...
-
Required Compliance [§206.6]
LULAs also are allowed as an alternative to platform lifts and private residence elevators....
-
Passing Spaces [1016.4]
Also, consider providing a minimum clear width of 60 inches if the ORAR is a boardwalk or otherwise not at the same level as the adjoining ground surface or if the edge is bordered by timbers...
-
M301.2.3 Transfer Sides
Obstructions shall not be vertically less than 1" (25 mm) nor be horizontally more than 3" (75 mm) from the edge of the patient support surface provide unobstructed access to the transfer...
-
Circulation Paths
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
- Hager Companies 4.5" Round Actuator 2-659-0166
- Northwest ADA Center
-
IDEA Center
This was usually a toe in the front and the trailing edge of the wheel, backpack or edge of the power base in the rear for manual and power wheelchairs....
- Hager Companies 6" Round Actuator 2-659-0162
- Hager Companies 6" Square Actuator 2-659-0170
- Hager Companies Security Pull P4E
- Hager Companies 4.5" Square Actuator 2-659-0173
- American Specialties Surface Mounted Vertical Soap Dispenser 20363
- Pressalit Care Lift for Manually Height Adjustable Worktop
- Mockett PCS67 Series Power & USB Bar
- Mockett PCS48D Clamp-On Horizontal E/E Power Dock