unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab...
Search Results "Grab Bar Clearance"
-
11B-608.5.2 Standard roll-in type shower compartments
-
607.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
607.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
- Jacknob Corp. 6080 ADA Concealed Latch - Straight Bar Partition Hardware
-
4.34.6 KITCHENS
Accessible or adaptable kitchens and their components shall be on an accessible route and shall comply with the requirements of 4.34.6.
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
- American Specialties Zamac Recessed Soap Dish with Bar 0410-Z
- Symmons Hand Shower T-600B-36-V
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors....
-
11B-608.5.3 Alternate roll-in type shower compartments
bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline at 39 inches (991 mm) to 41 inches (1041 mm) above the shower floor....
-
11B-608.5.3 Alternate roll-in type shower compartments
bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline at 39 inches (991 mm) to 41 inches (1041 mm) above the shower floor....
-
Protocol C Heights Obtained
27.0 30.0 33.3 34.3 We compared the two groups for transfer heights to/from the wheelchair to a level platform with and without grab...
-
Controls [4.21.5]
Grab bars are configured differently in showers with seats so that a person can lean back against the wall for support....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
Basic Features
Careful planning and design will incorporate elements such as a wider entrance door, adequate clear floor space, appropriate placement and models of fixtures and furniture, and grab bars...
-
H15
Is at least one wide toilet stall provided with an out swinging door, side and rear grab bars, and clear space next to the toilet?...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
- Landscape Structures Power Lifter™ Chinning Bar
-
1. Federal Laws and Regulations
But, for example, if DOT regulations require that a truck have 3 grab bars in specified places, and an otherwise qualified individual with a disability could perform essential job functions...
-
Alterations and Water Closet Clearances in Single-User Toilet Rooms With In-Swinging Doors (Section-by-Section Analysis)
or bathing rooms to swing into the required turning space, provided that there is sufficient clearance space for the wheelchair outside the door swing....
- The Corada Shop
-
M305.2 Transfer Supports (Section-by-Section Analysis)
With the changes to the final rule, the Board sought to harmonize as much as possible, these requirements with the 2004 ADA and ABA Accessibility Guidelines for grab bars. ...
-
11B-903.4 Back support
To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back....
