These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach....
Search Results "Side Grab Bar"
Commonly Searched Documents
-
11B-1008.4.2 Clear floor or ground space
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
-
Standard Stall
Stalls should be located and configured to allow forward or latch-side approaches which provide easier wheelchair access than hinge-side approaches....
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
1133B.2.4.2
Regardless of the occupant load, there shall be a floor or landing on each side of a door. 1133B.2.4.2 Maneuvering clearances at doors. ...
-
1008.3.2.3 Transfer Supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
11B-104.1.1 Construction and manufacturing tolerances
Where the requirement states a specified range, such as in Section 11B-609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate...
-
R406 Reach Ranges (Section-by-Section Analysis)
R406 Reach Ranges (Section-by-Section Analysis) Forward and side reach ranges must be between 380 millimeters (1.25 feet) and 1220 millimeters (4 feet) above the finish surface....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
R305.2.5 Pedestrian At-Grade Rail Crossings
At pedestrian at-grade rail crossings not located within a street or highway, detectable warning surfaces shall be placed on each side of the rail crossing....
-
Surface and Size [§305.2 and §305.3]
The minimum size (30” by 48”) applies whether the space is positioned for forward or side approaches....
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
Parking Spaces [4.6.3]
For vans with side-mounted lifts, a combined width of almost 17 feet is often needed for the deployment and use of side-mounted lifts; ADAAG requires at least 16 feet....
-
III-7.8200 Restaurants and cafeterias
ADAAG contains requirements for counters and bars, access aisles, food service lines, tableware and condiment areas, raised speaker's platforms, and vending machine areas (but not controls...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
-
Clear Ground Space [1011.2]
Fire rings, grills, fireplaces, and woodstoves 48 by 48 inches on all usable sides of a fire ring, grill, fireplace, and woodstove....
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
5. Bed with clear floor space
Bed with clear floor space for a side approach next to bed....