One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
Search Results "Side Grab Bar"
Commonly Searched Documents
-
4.2.4.2 RELATIONSHIP OF MANEUVERING CLEARANCE TO WHEELCHAIR SPACES
-
Edge Protection [§405.9]
Edge protection is not required at: ramps no higher than 6” that have side flares ramp landings serving an adjoining run or stairway sides of ramp landings with...
-
Clear Floor or Ground Space: ADA Standard Section 1008.4.2
These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach....
-
11B-1008.4.2 Clear floor or ground space
These dimensions apply to either forward or side reaches. The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach....
-
11B-403.5.1 Clear width
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides....
-
Components: ADA Standard Section 402.2
Section 402.2 covers the current ADA Standards for components of an accessible routes.
-
11B-810.6.3 Station names
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-802.1.2 Width
It should be noted that although side access to the wheelchair space is allowed, companion seating in compliance with Section 11B-802.3 must also be provided adjacent to each wheelchair...
-
407.12 Reach Height (Section-by-Section Analysis)
Specifically, this section would establish requirements for position (i.e., vertical reference plane), forward reach, and side reach....
-
11B-1009.5.2 Transfer space
by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
R305.1.3 Contrast
Visual contrast may be provided on the full surface of the curb ramp but should not extend to flared sides....
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
Transfer Platforms
ground level. 11 inches (280 mm) to 18 inches (455 mm) height of top surface Minimum 24 inches (610 mm) wide Minimum 14 inches (355 mm) deep Unobstructed side...
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
-
Standard Stall
Stalls should be located and configured to allow forward or latch-side approaches which provide easier wheelchair access than hinge-side approaches....
-
1008.3.2.3 Transfer Supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
1133B.2.4.2
Regardless of the occupant load, there shall be a floor or landing on each side of a door. 1133B.2.4.2 Maneuvering clearances at doors. ...
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
- Halsey Taylor Bi-Level HAC Green Cooler with Hydroboost® Bottle Filler
- Equalizer 1000 Series Exercise Machine
- American Standard Madera 1.28 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Side View
- American Standard Madera 1.6 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View