to keep a shoe heel or crutch tip from slipping on a walking surface under conditions likely to be found on the surface....
Search Results "End Transfer Surface"
-
I. Slip Resistant Surface—Aisles, Steps, Floor Areas Where People Walk, Floor Areas in Securement Locations, Lift Platforms, Ramps
-
4.8.5* HANDRAILS
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface....
- GE Artistry™ Series 30" Free-Standing Electric Range ABS45DFWS
- Varidesk LLC. Pro Desk 60™ Height-Adjustable Standing Desk
-
1016.8.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
Section 4.26.2
• Section 4.26.2 of the 1991 Standards requires handrail gripping surfaces to have a diameter of 1 ¼ inches to 1 ½ inches, or to provide an equivalent gripping surface....
-
610.3 Shower Compartment Seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry....
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1016.8.3 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, slopes not steeper than 1:20 shall be permitted when necessary for drainage....
- Figure 1009.5.7 Grab Bars – Drawing from the U.S. Access Board
- Diversified Woodcrafts Forward Vision ADA Workstation 2956KF-L-ADA
-
Q9: Pavement Preservation Treatment Types
Q9: Several pavement preservation treatment types are not listed in the technical assistance. If the treatment type is not specifically on the list of maintenance treatments, is it...
-
Assumptions
Assumptions Two industry standard specifications are used to determine the safety and accessibility of each surface: ASTM F1292‒99/04 Standard Specification for Impact Attenuation of...
- Diversified Woodcrafts Forward Vision ADA Workstation 2946KF-L-ADA
-
610.3 Shower Compartment Seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry....
-
610.3 Shower Compartment Seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry....
-
T208.1 General
A passenger access route shall consist of a route complying with T208.2 between wheelchair spaces and doorways, walking surfaces complying with T302, and clearances complying with T504....
-
1. Desk size
Desk size: If provided, the writing surface of desks and writing tables is no higher than 34 inches....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
- GE® 24" Standard Clean Free-Standing Gas Range JGAS02SENSS
-
M305.1 General
Supports shall comply with M305.
-
M305.1 General (Section-by-Section Analysis)
This is an introductory section.
-
M305.1 General
Supports shall comply with M305, as applicable.
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...