Because the 2010 NPRM proposed additional maneuvering clearances for wheelchair spaces, this exception was not germane and, therefore, did not appear in the proposed rule....
Search Results "Handrail Clearance"
Commonly Searched Documents
-
T602 Wheelchair Spaces
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
Design Opportunity
The pictured example vanity using the stock bracket and dimensions shown in section view may not provide the required minimum 8" deep knee clearance at 27" AFF under the vanity top (306)...
-
404 Doors, Doorways, and Gates
operated doors: clarify coverage of gates and the application of this section to manual doors and doorways intended for user passage (404.2) clarify and modify maneuvering clearance...
-
Can access be provided after construction based on need?
accessed through an individual’s private office for his or her exclusive use are not required to be built with certain specifically enumerated access features, such as grab bars and lavatory clearances...
-
§ 38.83(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas...
-
Expert Report of Ken Schoonover, P.E., KMS Associates, Inc. (August 7, 2018)
Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2)....
- Delta Widespread Lavatory Faucet 3552-MPU-DST
- Welch Allyn Scale-Tronix® Integrated Scales
- 2101KL HR Digital Platform Scale with Mechanical Height Rod
-
A4.2.1(1) Space Requirements for Wheelchairs
Thus, a minimum clear width of 32 in (815 mm) will provide adequate clearance....
-
A4.2.1(1) Space Requirements for Wheelchairs
Thus, a minimum clear width of 32 in (815 mm) will provide adequate clearance....
-
Construction and Manufacturing Tolerances
Grab Bar Diameter and Clearance...
-
F. Consultation with Food and Drug Administration
The FDA-CDRH may develop a guidance document to inform manufacturers how it intends to apply its regulatory authority to clearance or approval of medical devices addressed in the Access...
-
406 Curb Ramps
revised to: clarify requirements for cross slope (406.1) modify specifications for side flares (406.3) and landings (406.4) delete unnecessary language concerning handrails...
- Just Manufacturing Ledgemount Non-Swivel Gooseneck Concealed Mixing Faucet
- Rockwood Manufacturing Company 11047 Series 47 Straight Single Bar Set 8" Pull CTC
- Activar Hiawatha 535/509/536/537 Solid 1 inch Diameter Pulls
- Guardian Barrier-Free WideArea™ Eye/Face Wash GBF1724
-
2.5.1 U.S. Food and Drug Administration
Class I devices typically do not require any form of premarket clearance or approval from the FDA, but the manufacturers are still required to follow the FDA Quality System Regulation (in...
-
Acceleration
This affects calculations for both minimum green time for traffic signals and for pedestrian clearance intervals....
-
4.1 Introduction
One obvious example of the need to revise standards is that WhMD users who require the highest knee clearances cannot be accommodated without making some radical changes to the design of...
-
Feature 6 - Restrooms
An accessible lavatory has floor space in front so that a wheelchair user can approach it, knee clearance so the person can pull under it, and a lowered top surface height so the person...