Elevator Car Dimensions (§407.4.1)...
Search Results "Visible Indicator (Elevator Car)"
Commonly Searched Documents
-
Elevator Car Dimensions (§407.4.1)
-
Audible and Visual Indicators: ADA Standard Section 708.2
Advisory 708.2 Audible and Visual Indicators. A light can be used to indicate visually that assistance is on the way....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
Car Dimensions and Doors: ADA Standard Section 408.4.1
Section 408.4.1 covers the current ADA Standards for the car dimensions and doors of limited-use/limited-application elevators.
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.4.8.2.3 Frequency
407.4.8.2.3 Frequency. The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable....
-
11B-407.4.7.1 Buttons
Car control buttons shall comply with Section 11B-407.4.7.1....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-708.2 Audible and visual indicators
Advisory 11B-708.2 Audible and visual indicators. A light can be used to indicate visually that assistance is on the way....
-
Inside Dimensions of Elevator Cars: ADA Standard Section 409.4.1
Section 409.4.1 covers the current ADA Standards for the inside dimensions of private residence elevator cars.
-
Type: ADA Standard Section 407.4.7.1.1
Section 407.4.7.1.1 covers the current ADA Standards for type of designations and indicators required on elevator car control button.
- Federal Elevator 360 Passenger Elevator
-
Hall Lanterns [4.10.4]
Audible signals serve people with visual impairments by indicating which car is answering the call and its travel direction....