The shower pedestal or wall with the shower heads must be at the rear end of the clear ground space. At least one hand-held shower spray unit must be provided....
Search Results "Shower Enclosure"
Commonly Searched Documents
-
Outdoor Rinsing Showers [1011.2, 1011.3, and 1011.7]
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
11B-608.2 Size and clearances for shower compartments
11B-608.2 Size and clearances for shower compartments. Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
608.2.2 Standard Roll-In Type Shower Compartments....
-
Alternate Roll-in Showers
Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3)....
-
11B-608.2.1 Transfer type shower compartments
mm) wide minimum entry on the face of the shower compartment....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
11B-608.2.2 Standard roll-in type shower compartments....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
4.21.3 Seat
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
11B-806.2.4 Toilet and bathing facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of Sections 11B-603 through 11B-610....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.5.1 Reserved
[2010 ADAS] 608.5.1 Transfer Type Shower Compartments....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
-
Shower Spray Controls
Shower Spray Controls....
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...