Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
Search Results "Maneuvering Clearance (Alcove)"
Commonly Searched Documents
-
404.2.4.4 Floor or Ground Surface
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. ...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1....
-
11B-305.4 Knee and toe clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-306.3 Knee clearance
[See subsections ...]
-
11B-306.2 Toe clearance
[See subsections ...]
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering...
-
Standard Units
Recessing units in alcoves, wing walls, or other means of providing a detectable leading edge at or below 27 inches are acceptable....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
- Access Board: Doors in a Series
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
11B-604.8.1.1.1 Maneuvering space with in-swinging door....
-
Clear Floor Space [§309.2]
If clear floor space is obstructed on both sides more than half the minimum required depth, a wider clearance (36” min.) is required for maneuvering and sway....
-
4.5 Maneuvering Clearances
4.5 Maneuvering Clearances Figures 28-29 and Tables 7-8 show the standards from the four countries related to maneuvering clearances from a wheeled mobility device....
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
Clear Floor Space [4.19.3]
Recommendations:Consider locating towel dispensers within reach from the lavatory so that people can dry their hands before maneuvering wheelchairs....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....