Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
Search Results "Maneuvering Clearance (Alcove)"
-
Doors
-
Doorways at Landings [§405.7.5]
Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
-
Recessed Doors and Gates [§404.2.4.3]
If any obstruction within 18” of the latch side projects more than 8” from the face of a door or gate, maneuvering clearances for a forward approach must be provided....
- Figure 404.2.4.2(a) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.1(a) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Pull Side – Drawing from the U.S. Access Board
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm)....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm)....
- Figure 404.2.4.2(b) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.2(d) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.2(c) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
-
Forward Approach: ADA Standard Section 305.7.1
Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach.
-
Parallel Approach: ADA Standard Section 305.7.2
Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach.
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm)....
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm)....
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm)....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm)....
-
Platform to Hoistway Clearance: ADA Standard Section 408.4.3
Section 408.4.3 covers the ADA Standards for the required clearance between the car platform and the hoistway landing of limited-use/application elevators.
-
6.3(1)
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement in 4.13.6 for maneuvering space at the latch side of the door if the door is...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
- Figure 404.2.4.1(c) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...