(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
Search Results "Low Energy Door"
Commonly Searched Documents
-
A4.13.11(2) Sliding or folding doors
-
A4.13.12 Automatic Doors and Power-Assisted Doors
Sliding automatic doors do not need guard rails and are more convenient for wheelchair users and visually impaired people to use....
-
A4.13.12 AUTOMATIC DOORS AND POWER-ASSISTED DOORS
Sliding automatic doors do not need guard rails and are more convenient for wheelchair users and visually impaired people to use....
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
Reopening Device: ADA Standard Section 407.3.3
Section 407.3.3 covers the current ADA Standards for elevator reopening devices.
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
-
11B-404.2.9 Door and gate opening force
SECTION TITLE NOTES 11B-404.2.9 Door and gate opening force....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
5.1.9 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...