Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
Search Results "Elevator Hall Signal"
-
11B-411.2.1.4.2 Security or access controls
-
Elevator Door Requirements: ADA Standard Section 407.3
Section 407.3 covers the current ADA Standards for elevator door requirements.
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3....
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3....
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3....
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4....
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4....
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4....
-
Inside Dimensions of Elevator Cars: ADA Standard Section 409.4.1
Section 409.4.1 covers the current ADA Standards for the inside dimensions of private residence elevator cars.
-
11B-411.2.1.4.1 Hall call console additional buttons
Hall call console buttons provided in addition to the accessibility function button and keypad buttons shall comply with Section 11B-411.2.1.4.1. ...
-
11B-411.2.1.4.1 Hall call console additional buttons
Hall call console buttons provided in addition to the accessibility function button and keypad buttons shall comply with Section 11B-411.2.1.4.1....
-
11B-411.2.1.4.1 Hall call console additional buttons
Hall call console buttons provided in addition to the accessibility function button and keypad buttons shall comply with Section 11B-411.2.1.4.1....
-
Preserving elevator access in building where it might not be required.
Each story less than 3000 square feet, so elevator would likely not be required if built new. 2010 Standards 206.2.3, Exception 1. ...
-
§ 38.53(c) Signals
(c) Signals. Auditory and visual warning signals shall be provided to alert passengers of closing doors....
-
§ 38.73(c) Signals
(c) Signals. Auditory and visual warning signals shall be provided to alert passengers of closing doors....
-
R306.3.2 Pedestrian Activated Signals
Signals shall clearly identify which pedestrian street crossing segment the signal serves. Advisory R306.3.2 Pedestrian Activated Signals....
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_.
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION: Existing call...
-
409.2 Call Buttons
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309.
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_.
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309.