[ADA Stds 4.13.6, figure 25] Note: The maximum threshold height is 1/2 inch for new construction....
Search Results "Beveled Threshold"
Commonly Searched Documents
-
D4. Door Clearance
-
Accessible - Changes in Level
Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2. Changes in level greater than 1/2" shall be accomplished by means of a ramp....
-
(c) Thresholds at patio, deck or balcony doors
The final Guidelines provide that exterior deck, patio, or balcony surfaces should be no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they...
- SafePath SafeShower™ Ramp Transitions
- Access Board: Changes in Level
- The Corada Shop
-
404.2.4.4 Floor or Ground Surface
Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
404.2.4.4 Floor or Ground Surface
Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
Exception 8
When the adjusted construction cost is less than or equal to the current valuation threshold, as defined in Chapter 2, Section 202, the cost of compliance with Section 11B-202.4 shall be...
-
DSA IR 11B-2: BEVELED LIP AT CURB RAMPS (with revisions issued through Jan. 2011)
(In the 2007 and 2010 CBC this issue has been addressed by removing the requirement for a beveled lip at curb ramps.)...
-
404.2.4.4 Floor or Ground Surface
Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
11B-404.2.4.4 Floor or ground surface
Changes in level at thresholds complying with Section 11B-404.2.5 shall be permitted....
-
11B-404.2.4.4 Floor or ground surface
Changes in level at thresholds complying with Section 11B-404.2.5 shall be permitted....
- SafePath SAFELIFT™ Platform Weightlifting Surface
- EZ-ACCESS Transitions® Modular Entry Ramp
-
11B-404.2.4.4 Floor or ground surface
Changes in level at thresholds complying with Section 11B-404.2.5 shall be permitted....
- SafePath EntryLevel™ Landings
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
T502.3 Doorways with Level Boarding
Doorways on non-rail vehicles designed for level boarding bus systems shall comply with T502.3.
-
4(6)
(6) At the primary entry door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no...
-
PEMKO 1-3/8" Floor Plates/Safety Treads Product No.195
Requires the Premium User plan or above. (Login or upgrade your account!)
-
California DSA: Valuation Threshold for Alterations, Structural Repairs or Additions to Existing Buildings
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-604 Water closets and toilet compartments
Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum slope of ¼ inch per foot to a drain (refer to CPC Section 408.5 and CBC Section 11B-608.9), and a threshold...
-
Entrances
Additionally, the door hardware must not require tight grasping, pinching, or twisting, and the height of the door threshold must not be greater than ½ inch....