Thresholds, if provided at doorways, shall be ½ inch (12.7 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with Sections 11B-302 and 11B-303....
Search Results "Beveled Threshold"
Commonly Searched Documents
-
11B-404.2.5 Thresholds
-
Thresholds: ADA Standard Section 404.2.5
Section 404.2.5 covers the current ADA Standards for thresholds at doors.
-
Beveled: ADA Standard Section 303.3
Section 303.3 covers the current ADA Standards for beveled level changes.
-
Threshold Height
Section 404.2.5 addresses the height of thresholds....
-
Thresholds [§404.2.5]
Thresholds [§404.2.5] The height of thresholds is limited to 1/2” in new construction. The edge must be beveled 1:2 maximum above a height of 1/4”....
-
D5. Raised Threshold
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
4.13.8* Thresholds at Doorways
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
4.13.8* THRESHOLDS AT DOORWAYS
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
11B-404.2.5 Thresholds
Thresholds, if provided at doorways, shall be ½ inch (12.7 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with Sections 11B-302 and 11B-303....
-
11B-404.2.5 Thresholds
Thresholds, if provided at doorways, shall be ½ inch (12.7 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with Sections 11B-302 and 11B-303....
-
11B-404.2.5 Thresholds
Thresholds, if provided at doorways, shall be ½ inch (12.7 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with Sections 11B-302 and 11B-303....
-
404.2.5 Thresholds
404.2.5 Thresholds. Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
Thresholds at Doorways [4.13.8]
Thresholds at Doorways [4.13.8] Thresholds complicate wheelchair maneuvering through doors, especially at doors equipped with closers....
-
4.1.6(3)(d)(ii)
(ii) If existing thresholds are 3/4 in high or less, and have (or are modified to have) a beveled edge on each side, they may remain....
-
A4.13.8 Thresholds at Doorways
Thresholds and surface height changes in doorways are particularly inconvenient for wheelchair users who also have low stamina or restrictions in arm movement because complex maneuvering...
-
A4.13.8 THRESHOLDS AT DOORWAYS
Thresholds and surface height changes in doorways are particularly inconvenient for wheelchair users who also have low stamina or restrictions in arm movement, because complex maneuvering...
-
D5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...
-
4.1.6(4)(d)
(ii) If existing thresholds measure 3/4 in (19 mm) high or less, and are beveled or modified to provide a beveled edge on each side, then they may be retained....
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 11B-303.3 Beveled....
-
1132A.4.1 Thresholds
Changes in height at interior door thresholds (e.g., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm)....