Diagnostic scanning equipment using magnets, x-rays, or detectors into which a patient and the table on which the patient lies is inserted into the equipment through a cylindrical opening...
Search Results "Imaging Equipment with Bores"
Commonly Searched Documents
-
Imaging equipment with bores
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301) The Committee recommends a transfer surface size on imaging equipment be a minimum of 28 inches long by a minimum...
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301) The Committee recommends the use of alternative means of access by an overhead lift in place of clearances in...
-
4.3 Diagnostic Imaging Equipment
4.3 Diagnostic Imaging Equipment Diagnostic imaging equipment encompasses a broad range of technologies comprised of integrated systems of components and accessories with diverse designs...
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
5.2.1.4 Transfer Surface Size for Imaging Equipment. The transfer surface should be 28 inches wide minimum and 21 inches deep minimum....
-
7. Diagnostic Imaging Equipment: Accessibility Considerations
and transfer supports, for current diagnostic imaging equipment....
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the...
-
5.3.2.2 Transfer Sides for Imaging Equipment
5.3.2.2 Transfer Sides for Imaging Equipment. The transfer surface should be provided on at least one long side of the table....
-
4.3.4 Industry Considerations in Designing Accessible Imaging Equipment
4.3.4 Industry Considerations in Designing Accessible Imaging Equipment When considering applying accessibility standards to diagnostic imaging equipment, the MDE Advisory Committee recognized...
-
M301.2.2 Transfer Surface Size
Dependent on room layout and other ancillary equipment, both long sides of equipment with a bore tables may be available for transfer....
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment....
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment. Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces....
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the...
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented...
-
5.4.3.1 Positioning Support Height for Imaging Equipment
5.4.3.1 Positioning Support Height for Imaging Equipment. Positioning supports should be positioned 3 to 6 inches above the transfer surface....
-
M301.2.3 Transfer Surface Transfer Sides
Note: most installations can accommodate transfer from either long side for equipment with bores (siting and site dependent)....
-
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces For imaging equipment with transfer surfaces, the Committee recommends a positioning support...
-
4.3.2 Transfer Surfaces and Imaging Equipment Functions
4.3.2 Transfer Surfaces and Imaging Equipment Functions The transfer surface (table) of diagnostic imaging equipment serves two purposes: (1) it allows patients to be positioned properly...
-
4.3.5 Patient Positions During Diagnostic Imaging
4.3.5 Patient Positions During Diagnostic Imaging Finally, the vast majority of diagnostic imaging exams are conducted while patients are supine, prone, or side-lying on the table....
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Accessibility Standards for Medical Diagnostic Equipment Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations - Imaging Equipment Final Report June...
-
M301.3.1 Transfer Supports
Rationale: The subcommittee created this two part standard because the transfer surface in diagnostic imaging equipment is different than that of exam tables or chairs....